# Build a more efficient watering cycle
|
|
|
|
## Instructions
|
|
|
|
This lesson covered how to control a relay via sensor data, and that relay could in turn control a pump for an irrigation system. For a defined body of soil, running a pump for a fixed length of time should always have the same impact on the soil moisture. This means you can get an idea of how many seconds of irrigation correspond to a certain drop in soil moisture reading. Using this data you can build a more controlled irrigation system.
|
|
|
|
For this assignment you will calculate how long the pump should run for a particular rise in soil moisture.
|
|
|
|
> ⚠️ If you are using virtual IoT hardware, you can work through this process, but simulate the results by increasing the soil moisture reading manually by a fixed amount per second the relay us on.
|
|
|
|
1. Start with dry soil. Measure the soil moisture.
|
|
|
|
1. Add a fixed amount of water, either by running the pump for 1 second or by pouring a fixed amount in.
|
|
|
|
> The pump should always run at a constant rate, so every second the pump runs it should supply the same amount of water.
|
|
|
|
1. Wait until the soil moisture level stabilizes and take a reading.
|
|
|
|
1. Repeat this multiple times and create a table of the results. An example of this table is given below.
|
|
|
|
| Total Pump time | Soil Moisture | Decrease |
|
|
| --- | --: | -: |
|
|
| Dry | 643 | 0 |
|
|
| 1s | 621 | 22 |
|
|
| 2s | 601 | 20 |
|
|
| 3s | 579 | 22 |
|
|
| 4s | 560 | 19 |
|
|
| 5s | 539 | 21 |
|
|
| 6s | 521 | 18 |
|
|
|
|
1. Work out an average increase in soil moisture per second of water. In the example above, each second of water decreases the reading by an average of 20.3.
|
|
|
|
1. Use this data to improve the efficiency of your server code, running the pump for the required time to get the soil moisture to the level needed.
|
|
|
|
## Rubric
|
|
|
|
| Criteria | Exemplary | Adequate | Needs Improvement |
|
|
| -------- | --------- | -------- | ----------------- |
|
|
| Capture soil moisture date | Is able to capture multiple readings after adding fixed quantities of water | Is able to capture some readings with fixed quantities of water | Can only capture one or two readings, or is unable to use fixed quantities of water |
|
|
| Calibrate the server code | Is able to calculate an average decrease in soil moisture reading and update the serve code to use this | Is able to calculate an average decrease, but cannot update the server code, or is unable to correctly calculate an average, but uses this value to correctly update the server code | Is unable to calculate an average, or update the server code |
|